Precautions for installation and adjustment of cold storage doors

1. Check whether the gasket has cracks or tears. When the aligned door is closed, you should feel resistance. If you do not feel resistance, or if there are visible cracks or fissures, the sealing gasket should be replaced.

2. Check if the hinge is damaged, and if so, replace it promptly. The specific direction is as follows:

a、 Close the door tightly, grasp the top and bottom edges of the door near the hinge, gently pull it towards your direction, and check if the hinge is damaged or excessively moved;

b、 Open the door, grab the handle to raise or lower the door, and check if there is any excess movement in the hinge mechanism.

c、 Visually inspect the hinge;

If the hinge or shaft sleeve is damaged, please replace it in a timely manner.

Pry open the upper hinge cover and use a screwdriver or socket wrench to loosen the screws or bolts (align the control door of the upper hinge).

Tighten the screws or bolts.

Test the door several times. If the screw is loose, it can be re tightened or replaced.

Precautions

Precautions for adjusting the cold storage door

Precautions for installation of cold storage doors

The installation and adjustment of cold storage doors should pay attention to the following points:

HOME    Cold room knowledge    Precautions for installation and adjustment of cold storage doors